Luminex magnetic separator

MagPlex Microspheres, Luminex; ... They are magnetic, and with the use of a magnetic separator, they can be separated from solution quickly and easily. This improves percent recovery during handling and wash steps and facilitates assay automation. Available in 500 unique regions, enabling the development of assays which can measure up to 500

Get Price
  • Magnetic Separators
    Magnetic Separators

    Separate a single reaction tube or a whole plate of beads from solution during wash steps When handling MagPlex Microspheres, it will often be necessary to separate the magnetic beads from solutio

  • BioTek® microplate washers | Life Science Research | Merck
    BioTek® microplate washers | Life Science Research | Merck

    The Handheld Magnetic Separator Block offers a low cost alternative to automated washing of MILLIPLEX magnetic bead-based assays without loss in assay performance. The handheld magnetic separator enables you to remove the liquid contents of the 96-well plate by simply decanting or “flicking” the contents into a sink and blotting off the

  • PRINCIPLE OF THE LUMINEX MULTIPLEX BEAD
    PRINCIPLE OF THE LUMINEX MULTIPLEX BEAD

    Coupled with the Luminex xMAP platform in a magnetic bead format, you receive the advantage of ideal speed and sensitivity, allowing quantitative multiplex detection of dozens of analytes simultaneously, which can dramatically improve productivity. ... Magnetic Separation Block (EMD Millipore Catalog #40-285 or equivalent)

  • 96 Hole Magnetic Separation Rack | Thermo Fisher | Bioz
    96 Hole Magnetic Separation Rack | Thermo Fisher | Bioz

    The Magnetic 96 Well Separator is designed for fast and simple removal of supernatant from samples bound to magnetic particles and may be used manually or as an integrated part of an automated workstation The Magnetic 96 Well Separator is an ideal tool for use in singleplex and multiplex biological assays based on the Luminex xMAP Technology These assays make use of Luminex MagPlex or

  • Luminex Discovery Assay
    Luminex Discovery Assay

    Nov 18, 2021 Imager. Alternatively, kits can be used with the Luminex 100/200™, Luminex FLEXMAP 3D , Luminex INTELLIFLEX, or Bio-Rad Bio-Plex , dual laser, flow-based sorting and detection platforms. Analyte-specific antibodies are pre-coated onto magnetic microparticles embedded with fluorophores at set ratios for each unique microparticle region

  • Magnetics Business & Technology - September/October
    Magnetics Business & Technology - September/October

    Luminex offers two magnetic separators, one is a plate separator and the other a tube separator. The plate separator is a modified plate magnet intended to separate a 96-well plate of MagPlex microspheres during assay preparation steps. The side clasps on this magnet have been specially designed to hold a roundbottom plate securely to the

  • Handheld Magnetic Separator Block for 96 Well Flat
    Handheld Magnetic Separator Block for 96 Well Flat

    The Handheld Magnetic Separator Block offers a low cost option for biomagnetic separation. Magnets are positioned around the bottom of the well to pull the beads to the side of the well. The top magnetic frame is white polycarbonate, with a corrosion resistant steel plate underneath, all mounted to a polypropylene base

  • LifeSep magnetic separator unit 96P, for 96 well tray
    LifeSep magnetic separator unit 96P, for 96 well tray

    LifeSep magnetic separator unit 96P, for 96 well tray, deep well; find -Z740158 MSDS, related peer-reviewed papers, technical documents, similar products & more at Sigma-Aldrich

  • Bio-Plex Pro Magnetic COOH Beads Bio-Plex COOH
    Bio-Plex Pro Magnetic COOH Beads Bio-Plex COOH

    For magnetic or vacuum separation methods All regions are at a concentration of 1.25 x 10 7 beads/mL MC10026-01 Bio-Plex Pro Magnetic COOH Beads, Region 26, 1 ml MC10027-01 Bio-Plex Pro Magnetic COOH Beads, Region 27, 1 ml MC10028-01 Bio-Plex Pro Magnetic COOH Beads, Region 28, 1 ml MC10029-01 Bio-Plex Pro Magnetic COOH Beads, Region 29, 1 ml

  • User Manual - Thermo Fisher Scientific
    User Manual - Thermo Fisher Scientific

    On Day 2 of the assay, turn on and initiate startup protocol of the Luminex machine according to the manufacturer’s instructions. It takes 30 min for the lasers to warm-up. If you are running assays on your Luminex instrument that uses both Magnetic Separation Plates

  • xMAP Cookbook 2nd Edition
    xMAP Cookbook 2nd Edition

    Dec 31, 2014 Clip the plate in place on the Luminex Magnetic Plate Separator and rapidly and forcefully invert over a biohazard receptacle to evacuate the liquid from the wells. Note: For information on the MagPlex Manual Wash Method, please visit the Magnetic Separators page at www.luminexcorp.com. 11. Wash each well with 100 μL of assay buffer by gently

  • Luminex Magnetic Plate Separator CN-0269-01: R&D Systems
    Luminex Magnetic Plate Separator CN-0269-01: R&D Systems

    The Luminex Magnetic Plate Separator is a modified plate magnet intended to separate a 96-well plate of MagPlex Microspheres during assay preparation steps. The side clasps on this magnet have been specially designed to hold a round-bottom plate securely to the magnet, enabling the user to quickly decant it over a waste container

  • Magnetic 96-Well Separator - Thermo Fisher Scientific
    Magnetic 96-Well Separator - Thermo Fisher Scientific

    The Magnetic 96-Well Separator is designed for fast and simple removal of supernatant from samples bound to magnetic particles and may be used manually or as an integrated part of an automated workstation. The Magnetic 96-Well Separator is an ideal tool for use in singleplex and multiplex biological assays based on the Luminex™ xMAP™ Technology. These assays make use of

  • Magnetic Separators - Luminex Corp
    Magnetic Separators - Luminex Corp

    Magnetic Separators. Designed for use with MagPlex xMAP assays, use these to separate a single reaction tube or a whole plate of beads from solution during wash steps

  • xMAP® Instrument Reagents: R&D Systems
    xMAP® Instrument Reagents: R&D Systems

    The Luminex Magnetic Plate Separator is a modified plate magnet intended to separate a 96-well plate of MagPlex Microspheres during assay preparation steps. The side clasps on this magnet have been specially designed to hold a round-bottom plate securely to the magnet, enabling the user to quickly invert and decant it over a waste container

  • xMAP Antibody Coupling Kit User Manual
    xMAP Antibody Coupling Kit User Manual

    With Luminex MagPlex microspheres, if the kit protocol is performed carefully, the percent recovery of the coupling reaction is typically 90% or greater; enough for more than forty- five 96-well plates (@ 2,500 beads/well) for every

  • Development, Characterisation and Application of
    Development, Characterisation and Application of

    Jul 19, 2016 The tubes were placed on the magnetic separator and the supernatant was carefully discarded by pipetting. The beads were washed once with PBS, re-suspended in 125 μl of antibody buffer, transferred to a microtitre plate and analysed on the Luminex. A reading of greater than 2000 MFI in the positive tube signified successful coupling